Back

Installation:

Installation should be in accordance with ASTM D 6462, Standard Practice for Silt Fence Installation, or local council specifications. The sediment can be contained and channelled into lined holding ponds. Install using a silt fence trenching machine, if available.

The marker lines are 150 mm from the edge and are designed as guides for proper burial depth during trenching process. In absence of the proper machinery several other methods are used, as follows.

Method 1: This procedure is primarily based upon Auckland Regional Council Sediment Control Guidelines (TP90): A trench is constructed, to a width of 100 mm x 200 mm depth, minimum. Proper installation requires the Silt Fence be anchored in the trench preferably with the fabric covering the bottom of the trench. Backfill using earth moving equipment.

Stakes should be either tantalised timber of 50 mm square or steel waratahs of 1.5 m length. Drive the stakes into the ground to a minimum depth of 400 mm, or 600 mm on a slope of 3:1 or greater. Spacing of stakes or waratahs is at a minimum distance of 2 m apart. Always install the silt fence with the stakes behind the flow.

Support fence is recommended to be installed along the entire length along the upslope side of the fence from the top to the bottom of the silt fence. A support wire (2.5 mm galvanised) is attached along the top of the fence.

Method 2: A faster (less effective) method is to drive the stakes into the ground and fasten the silt fence with the guideline at ground level allowing a 200 mm flap which is covered with earth.

As this method may not totally prevent sediment flow under the fence it may not be allowed under the District Plan, therefore check for compliance.

Back

PHYSICAL PROPERTIES
SYNTEX SILTFENCE
PROPERTY TEST METHOD UNITS Type 1 Type 2
Mechanical
Grab Tensile Strength ASTM D 4632 N 974 x 818 779 x 645
Grab Elongation ASTM D 4632 % 29 x 28 20 x 20
Puncture Strength ASTM D 4833 N 373 556
Mullens Burst ASTM D 3786 kPa 2496 2929
Trapezoidal Tear ASTM D 4533 N 551 x 480 423
Hydraulic
AOS ASTM D 4751 mm 0.386 0.425
Permittivity ASTM D 4491 sec -1 0.07 1.30
Water Flow Rate ASTM D 4491 l/min/ m2 245 4074
Endurance
UV Resistance (500 hrs) ASTM D 4355 % retained 95 95
Standard packaging
Roll Width Measured m 0.915 0.915
Roll Length Measured m 50 50

The data in all tables is intended as guides only and is not intended as a warranty or guarantee. Permathene Ltd. reserves the right to change the specification contained herein without notice.