Back

PHYSICAL PROPERTIES - SILT FENCE
SYNTEX SILTFENCE
PROPERTY TEST METHOD UNITS Type 1 Type 2
Mechanical
Grab Tensile Strength ASTM D 4632 N 552 x 454 779 x 645
Grab Elongation ASTM D 4632 % 16 x 20 20 x 20
Puncture Strength ASTM D 4833 N 267 556
Mullens Burst ASTM D 3786 kPa 2068 2929
Trapezoidal Tear ASTM D 4533 N 289 x 289 423
Hydraulic
AOS ASTM D 4751 mm 0.5 0.425
Permittivity ASTM D 4491 sec -1 0.1 1.30
Water Flow Rate ASTM D 4491 l/min/ m2 407 4074
Endurance
UV Resistance (500 hrs) ASTM D 4355 % retained 80 95
Standard packaging
Roll Width Measured m 1.2 0.915
Roll Length Measured m 100 100

The data in all tables is intended as guides only and is not intended as a warranty or guarantee. Permathene Ltd. reserves the right to change the specification contained herein without notice. Updated March 2009