Installation Procedure

  1. Filter Fabric (600mmwidth) is rolled along the base of the wall allowing at least 150 mm to sit against the wall and Filter Pipe modules placed in a long row.
  2. Wall drain panels are placed flush against the wall above the Filter Pipe detaching the 100 mm flap at the base rear of the panel to allow complete coverage across the Filter Pipe.
  3. Each consecutive Walldrain panel is placed adjacent to one another inside the100 mm sleeve and secured to the wall's surface (interlocking is not required).
  4. Overlap the remaining filter fabric from the 600 mm roll across the Filter Pipe and secure all seams along the base of the wall and between each panel using adhesive tape.
  5. Outlet Pipes are fitted in to the sleeve at the end of the Filter Pipe and secured using adhesive tape.
  6. The base is backfilled with coarse washed river sand (more is better than less) approx 300 mm height.
  7. The System is backfilled with normal fill avoiding clay elements.

Back

WALLDRAIN PROPERTIES
Property Value
Core Thickness 30 mm
Panel Width 1068 mm
Height Up to 2.85 m
Weight 3 kg/sqm
Compressive Strength > 1500 kPa
Drainage Capacity 14400 l/h/sqm
Service Temperature -30 C to +120 C
FILTER PIPE PROPERTIES
Property Value
Core Thickness 60 mm
Module Width 178 mm
length 1068 mm, 2136 mm
Weight 1 kg/lm
Vertical Surface Void > 65%
Volume Void > 101 l/m
Compressive Strength > 1500 kPa
Drainage Capacity > 14400 l/h/sqm
Service Temperature -30 C to +120 C
Material Polypropylene
Filter Fabric Polypropylene

The data in all tables is intended as guides only and is not intended as a warranty or guarantee. Permathene Ltd. reserves the right to change the specification contained herein without notice.