Back
PHYSICAL PROPERTIES - ARMATEX M
|
Armatex M: woven geogrid for soft soil reinforcing (woven grid made from high tenacity PVA yarns with pvc coating)
|
|
Technical
|
Method
|
Units
|
20/20
|
35/20
|
40/40
|
55/30
|
65/65
|
80/30
|
80/80
|
110/30
|
|
Tensile strength
EN ISO 10319
|
MD min.
|
kN/m
|
25
|
40
|
45
|
60
|
75
|
90
|
90
|
130
|
|
CD min.
|
kN/m
|
25
|
25
|
45
|
35
|
75
|
35
|
90
|
35
|
|
tolerances MD, CD
|
-5
|
-5
|
-5
|
-5
|
-10
|
-10, -5
|
-10
|
-20, -5
|
|
Strain at maximum load
EN ISO 10319
|
MD
|
%
|
5
|
6
|
5
|
5
|
5
|
6
|
5
|
6
|
|
CD
|
%
|
6
|
6
|
6
|
6
|
6
|
6
|
6
|
6
|
|
tolerances MD, CD
|
+/-1
|
+/-2
|
+/-1
|
+/-2
|
+/-1
|
+/-2
|
+/-1
|
+/-2
|
|
Technical
|
Method
|
Units
|
150/30
|
150/150
|
200/20
|
200/50
|
200/100
|
250/125
|
|
|
|
Tensile strength
EN ISO 10319
|
MD min.
|
kN/m
|
170
|
170
|
220
|
220
|
220
|
270
|
|
|
|
CD min.
|
kN/m
|
35
|
170
|
25
|
55
|
110
|
140
|
|
|
|
tolerances MD, CD
|
-20
|
-20
|
-20, -5
|
-20, -5
|
-20, -10
|
-20, -15
|
|
|
|
Strain at max. load
EN ISO 10319
|
MD
|
%
|
6
|
6
|
6
|
5
|
6
|
6
|
|
|
|
CD
|
%
|
6
|
6
|
6
|
6
|
6
|
6
|
|
|
|
tolerances MD, CD
|
+/-2
|
+/-1
|
+/-2
|
+/-1
|
+/-2
|
+/-2
|
|
|
|
Roll size
|
|
m
|
5 x 100
|
|
Mesh size
|
ISO 4648
|
mm
|
20 x 20 or 35 x 35
|
PHYSICAL PROPERTIES - ARMATEX G
|
Armatex G: woven geogrid for soft soil reinforcing (woven grid made from high tenacity PET yarns with pvc coating)
|
|
Technical
|
Method
|
Units
|
20/20
|
35/20
|
35/35
|
40/40
|
55/30
|
55/55
|
65/20
|
65/30
|
|
Tensile strength
EN ISO 10319
|
MD min.
|
kN/m
|
25
|
40
|
40
|
45
|
60
|
60
|
70
|
70
|
|
CD min.
|
kN/m
|
25
|
25
|
40
|
45
|
35
|
60
|
25
|
35
|
|
tolerances MD, CD
|
-5
|
-5
|
-5
|
-5
|
-5
|
-5
|
-5
|
-5
|
|
Strain at max. load
EN ISO 10319
|
MD
|
%
|
12.5
|
12.5
|
12.5
|
12.5
|
13
|
13
|
13
|
13
|
|
CD
|
%
|
12.5
|
12.5
|
12.5
|
12.5
|
13
|
13
|
13
|
13
|
|
tolerances MD, CD
|
+/-2.5
|
+/-2.5
|
+/-2.5
|
+/-2.5
|
+/-2.5
|
+/-2.5
|
+/-2.5
|
+/-2.5
|
|
Technical
|
Method
|
Units
|
65/65
|
80/30
|
80/80
|
110/30
|
110/110
|
150/30
|
150/50
|
150/150
|
|
Tensile strength
EN ISO 10319
|
MD min.
|
kN/m
|
75
|
90
|
90
|
130
|
130
|
170
|
170
|
170
|
|
CD min.
|
kN/m
|
75
|
35
|
90
|
35
|
130
|
35
|
55
|
170
|
|
tolerances MD, CD
|
-10
|
-10, -5
|
-10
|
-20, -5
|
-20
|
-20, -5
|
-20, -5
|
-20
|
|
Strain at max. load
EN ISO 10319
|
MD
|
%
|
12.5
|
12.5
|
13
|
13
|
13
|
13
|
12.5
|
14
|
|
CD
|
%
|
12.5
|
12.5
|
13
|
13
|
13
|
13
|
12.5
|
14
|
|
tolerances MD, CD
|
+/-2.5
|
+/-3.5
|
+/-2.5
|
+/-2.5
|
+/-2.5
|
+/-2.5
|
+/-3
|
+/-3
|
|
Technical
|
Method
|
Units
|
200/50A
|
200/50
|
300/50
|
|
|
|
|
|
|
Tensile strength
EN ISO 10319
|
MD min.
|
kN/m
|
200 |
220 |
330 |
|
|
|
|
|
|
CD min.
|
kN/m
|
55 |
55 |
55 |
|
|
|
|
|
| tolerances MD, CD |
-50, -5 |
-20, -5 |
-30, -5 |
|
|
|
|
|
|
Strain at max. load
EN ISO 10319
|
MD
|
%
|
12 |
18 |
14 |
|
|
|
|
|
|
CD
|
%
|
12 |
13 |
13
|
|
|
|
|
|
|
tolerances MD, CD |
+/-3 |
+/-3, +/-2.5 |
+/-3, +/-2.5 |
|
|
|
|
|
| Roll Size |
m |
|
5 x 100 |
| Mesh Size |
ISO 4648 |
mm x mm |
20 x 20 or 35 x 35 |
The data in all tables is intended as guides only and is not intended as a warranty or guarantee. Permathene Ltd. reserves the right to change the specification contained herein without notice.