Back
PHYSICAL PROPERTIES
|
LIQUID BOOT
|
| TECHNICAL |
TEST METHOD |
VALUE |
|
WATERPROOFING
|
|
|
|
Soil Burial
|
ASTM E154-88
|
Passed
|
|
Water Penetration Rate
|
ASTM D2434
|
<7.75 x 10-9 cm/sec
|
|
Water Vapor Permeability
|
ASTM E96
|
0.24 perms
|
|
Water Vapor Transmission
|
ASTM E96
|
0.10 grains/h-ft2
|
|
POTABLE WATER
|
|
|
|
Toxicity Test
|
22 CCR 66696
|
Passed. CCR Bioassay - Flathead Minnow |
|
Potable Water Containment
|
ANSI/NSF 61
|
NSF Certified for tanks >1,365,000 ltr
|
|
GENERAL INFORMATION
|
|
|
|
Coefficient of Friction- geotextile both sides
|
ASTM D5321
|
0.72
|
|
Cold Bend Test
|
ASTM D146
|
Passed, no cracking at -31 C |
|
Freeze-Thaw Resistance (100 Cycles)
|
ASTM A742
|
Meets criteria. No spalling or disbondment
|
|
Accelerated Weathering & Ultraviolet Exposure
|
ASTM D822
|
No adverse effect after 500 hours
|
|
Hydrostatic Head Resistance
|
ASTM D751
|
Tested to 42m or 60psi
|
|
Elongation
|
ASTM D412
|
1,332% - 0 reinforcement, 90% recovery
|
|
Elongation- 315gsm non-woven geotextile both sides
|
ASTM D751
|
100% (same as geotextile tested separately)
|
|
Tensile Strength
|
ASTM D412
|
58 p.s.i. without reinforcement
|
|
Tensile Strength-315gsm non-woven geotextile both sides
|
ASTM D751
|
196 p.s.i. (same as geotextile tested separately)
|
|
Tensile Bond Strength to Concrete
|
ASTM D413
|
1162 kg/m2 uplift force
|
|
Puncture Resistance-315gsm non-woven geotextile both sides
|
ASTM D4833
|
130 kg travel of probe=19mm
|
|
Flame Spread
|
ASTM E108
|
Class A with top coat (comparable to UL790)
|
|
Electric Volume Resistivity
|
ASTM D257
|
1.91 x 1010 ohms-cm
|
The data in all tables is intended as guides only and is not intended as a warranty or guarantee. Permathene Ltd. reserves the right to change the specification contained herein without notice.